Skip to main content

Table 2 Selective comparison of densitometric results from 2D PAGE analyses under FIGE versus CFE conditions

From: Increase in local protein concentration by field-inversion gel electrophoresis

Spot number

Protein name

Pulsed (FIGE)

Control (CFE)

Percent Increase in Intensity (%)

  

Densitometric intensity#

1

Endoplasmin precursor

14414

8502

69

2

Regucalcin

11453

11006

4

3

Fructose-1,6-bisphosphatase

15358

13699

12.1

4

Malate dehydrogenase, cytoplasmic

14771

12522

17.9

5

Regucalcin Isoform

11266

*

N.A.

6

Lactoylglutathione lyase

8531

4603

85.3

7

Cytochrome b5

12585

5569

126

8

Glutathione S-transferase kappa1

18944

3813

396.8

9

Fatty acid-binding protein, liver

26493

6228

325.3

A

Internal calibrator

33593

31998

5

  1. #Densitometric results are given as the average of the intensity per unit area. For similar spots under comparison, approximately the same area was obtained for the calculation of intensity. * denotes that the software failed to detect any differences with respect to backgroud noise. All results were corrected for background noise. Percent enhanced intensity is the percentage of increase in intensity using the intensity values of CFE as the denominator and the difference in intensity as the numerator. N.A., Not available.